Product catalog

Find your part.

Search by part number or keyword. Every part has its own page, so search engines can find them individually too.

Part numberDescription
3VT2716-3AP36-0AA0 circuit breaker 3VT2 high breaking capacity Icu=36kA, 415V AC 3-pole; circuit breaker with ETU motor/transformer protection ETU MP, LI IR=63…160A, overload protection…
3VT2720-2AB36-0AA0 circuit breaker 3VT2 standard breaking capacity Icu=36kA, 415V AC 3-pole; circuit breaker with ETU 3-pole, line protection ETU LP, LI IR=200A, overload…
3VT2720-2AB56-0AA0 CIRCUIT BREAKER 3VT2 STANDARD BREAKING CAPACITY ICU=36KA, 415V AC 4-POLE; CIRCUIT BREAKER N MEASURED + SWITCHED W/OVERCURRENT RELEASE 3-POLE, SYSTEM PROTECTION ETU…
3VT2725-2AA33-0AA0 CIRCUIT BREAKER 3VT2 STANDARD SWITCHING CAPACITY ICU=36KA, 415V AC 3-POLE; CIRCUIT BREAKER W/O ELECTRONIC TRIP UNIT W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM…
3VT2725-2AA36-0AA0 circuit breaker 3VT2 standard breaking capacity Icu=36kA, 415V AC 3-pole; circuit breaker w/o Electronic Trip Unit without auxiliary release without auxiliary/alarm switch
3VT2725-2AA46-0AA0 circuit breaker 3VT2 standard breaking capacity Icu=36kA, 415V AC 4-pole; circuit breaker w/o Electronic Trip Unit N connected without auxiliary release without…
3VT2725-2AA56-0AA0 circuit breaker 3VT2 standard breaking capacity Icu=36kA, 415V AC 4-pole; circuit breaker w/o Electronic Trip Unit N connected+measured without auxiliary release without…
3VT2725-2AB36-0AA0 circuit breaker 3VT2 standard breaking capacity Icu=36kA, 415V AC 3-pole; circuit breaker with ETU 3-pole, line protection ETU LP, LI IR=250A, overload…
3VT2725-2AB46-0AA0 CIRCUIT BREAKER 3VT2 STANDARD BREAKING CAPACITY ICU=36KA, 415V AC 4-POLE; CIRCUIT BREAKER N SWITCHED W/OVERCURRENT RELEASE 3-POLE, SYSTEM PROTECTION ETU LP, LI…
3VT2725-2AC36-0AA0 CIRCUIT BREAKER 3VT2 STANDARD BREAKING CAPACITY ICU=36KA, 415V AC 3-POLE; CIRCUIT BREAKER W/OVERCURRENT RELEASE SYSTEM PROTECTION ETU DP, LI IR= 100…250A, OVERLOAD…
3VT2725-2AP36-0AA0 circuit breaker 3VT2 standard breaking capacity Icu=36kA, 415V AC 3-pole; circuit breaker with ETU motor/transformer protection ETU MP, LI IR=100…250A, overload protection…
3VT2725-2AP46-0AA0 CIRCUIT BREAKER 3VT2 STANDARD BREAKING CAPACITY ICU=36KA, 415V AC 4-POLE; CIRCUIT BREAKER N SWITCHED W/OVERCURRENT RELEASE MOTOR/TRANSF. PROTECTION ETU MP, LI IR=…
3VT2725-2AS56-0AA0 CIRCUIT BREAKER 3VT2 STANDARD BREAKING CAPACITY ICU=36KA, 415V AC 4-POLE; CIRCUIT BREAKER N MEASURED + SWITCHED W/OVERCURRENT RELEASE MOTOR/TRANSF. PROTECTION ETU MPS,…
3VT2725-2DE36-0AA0 switch disconnector 3VT2 3-pole; switch disconnector In=250A rated current without auxiliary release without auxiliary/alarm switch
3VT2725-2DT36-0AA0 switch disconnector 3VT2 standard breaking capacity Icu=36kA, 415V AC 3-pole; switch disconnector no overload protection no short-circuit protection without auxiliary release without…
3VT2725-2EE46-0AA0 switch disconnector 3VT2 4-pole; switch disconnector In=250A rated current without auxiliary release without auxiliary/alarm switch
3VT2725-3AA33-0AA0 CIRCUIT BREAKER 3VT2 HIGH SWITCHING CAPACITY ICU=65KA, 415V AC 3-POLE; CIRCUIT BREAKER W/O ELECTRONIC TRIP UNIT W/O AUXILIARY TRIP UNIT W/O AUXILIARY/ALARM…
3VT2725-3AA36-0AA0 circuit breaker 3VT2 high breaking capacity Icu=65kA, 415V AC 3-pole; circuit breaker w/o Electronic Trip Unit without auxiliary release without auxiliary/alarm switch
3VT2725-3AA46-0AA0 circuit breaker 3VT2 high breaking capacity Icu=65kA, 415V AC 4-pole; circuit breaker w/o Electronic Trip Unit N connected without auxiliary release without…
3VT2725-3AA56-0AA0 circuit breaker 3VT2 high breaking capacity Icu=65kA, 415V AC 4-pole; circuit breaker w/o Electronic Trip Unit N connected+measured without auxiliary release without…